Photodegradation Kinetic Study of Aceclofenac by HPTLC Method

 

Nilesh Patel1*, Shailesh Shah2, Ishwarsinh Rathod3, Dhaval Patel4 and Biraju Patel4

1Department of Pharmaceutical Sciences, Saurashtra University, Rajkot-360005, Gujarat, India.

2Department of Quality Assurance, Maliba pharmacy College, Bardoli, Gujarat, India.

3Department of Quality Assurance, L.M. College of Pharmacy, Ahmedabad-380009, Gujarat, India.

4Veerayatan Institute of Pharmacy, Mandvi-370460, Gujarat, India

*Corresponding Author E-mail: nkpatel99@gmail.com, dhaval_pharmacist@rediffmail.com.

 

ABSTRACT:

A simple, specific and precise HPTLC method was developed and validated for estimation of aceclofenac in photodegraded sample. The method involves separation of sample and photodegradation product on TLC aluminum sheets pre-coated with silica gel 60 F254 plate using a mixture of Toluene: Ethyl acetate: Glacial acetic acid: Methanol (6.00:1.00:0.20:0.15 v/v/v/v) as the mobile phase. Detection of the spot was carried out at 284nm in absorbance/reflectance mode. The retardation factor (Rf) for aceclofenac was found to be 0.35±0.03. The linearity range was found to be 50-150ng/spot with r2= 0.9931. The validated method was applied for determination of photodegradation kinetic study. Photodegradation reaction at various experimental conditions follows zero order kinetic and rate constant (K) was determined to be 0.4855 ng µl-1 min-1. T1/2 and T90% was found to be 116.78 min-1 and 23.35 min-1 respectively.

 

KEYWORDS: Photodegradation kinetics, Aceclofenac, HPTLC, Photostability.

 


 

INTRODUCTION:

Aceclofenac, a phenyl acetic acid derivative is used as an anti-inflammatory agent1. Aceclofenac is official in British pharmacopoeia2 and European pharmacopoeia3. Various methods like HPLC 4-10, HPTLC 11-13, spectrophotometric 4 -28 and others29-33 are reported in literature for analysis of aceclofenac. The Photodegradation and in vitro phototoxicity of aceclofenac are reported to evaluate phararmacological response of photodegradation product34. The literature survey revealed that no method has been reported for the photodegradation kinetic study of aceclofenac, therefore HPTLC method was developed and validated for the analysis of aceclofenac. The developed HPTLC method was used for the photodegradation kinetic study of aceclofenac solution.

 

EXPERIMENTAL:

Aceclofenac was obtained as a gift sample from Astron Research Ltd, Ahmedabad, India.  Methanol pre-washed TLC aluminum sheets of silica gel 60 F254, layer thickness 0.2 mm. 20 x 20 cm, E. Merck, Germany, were used as stationary phase. Toluene, ethyl acetate, glacial acetic acid and methanol (All AR grade, Rankem Labs Ltd) were used for mobile phase preparation.

 

A Camag HPTLC system comprising of CAMAG Linomat IV (semi automatic spotting device), CAMAG twin trough chamber, CAMAG TLC Scanner 3, CAMAG CATS 4 Software and Hamilton 100ml HPTLC syringe were used for study.

 

Preparation of Standard Solution of Aceclofenac:

Ten mg of Aceclofenac was weighed accurately and transferred into 10 ml volumetric flask (wrapped with aluminum foil).  It was dissolved and diluted to volume with methanol.  This solution (0.5 ml) was further diluted with methanol to volume in 10ml volumetric flask. Again 1.0 ml of diluted solution was further diluted with methanol to 10 ml in volumetric flask (5μg/ml).

 

HPTLC Method and Chromatographic Condition:

For plate washing, TLC aluminum sheets of silica gel 60 F254 (Precoated, 6.5 x 5.5 cm) was placed in twin trough glass chamber containing methanol as mobile phase and methanol was allowed to travel up to upper edge of plate (ascending method). Plate was removed and allowed to dry at 50o C for 10 min. The chromatographic estimation was performed using the following conditions. Stationary phase; methanol pre-washed TLC aluminum sheets of silica gel 60 F254 (layer thickness 0.2 mm. 20 x 20 cm), mobile phase; toluene: ethyl acetate: glacial acetic acid:  methanol (6.00:1:00.20.00:0.15 v/v/v/v), chamber saturation time; 45 min, distance run; 40 mm, scanning wavelength; 284 nm, scanning speed; 5mm/sec, slit dimension; 3.0 x 0.45 mm, temperature; 25± 2o C, band width; 3mm, space; 4mm, spraying rate; 10 sec/ml.

On pre-washed, pre-coated TLC aluminum sheets of silica gel 60 F254 10μl (50ng), 15μl (75ng), 20μl (100ng), 25μl (125ng) and 30μl (150ng) of standard solution of aceclofenac were spotted. The plate was dried for 5 min at 500 C and developed in previously saturated twin trough chamber at constant temperature 25±20 C using mobile phase. After development the plate was dried at 500 C for 10 min. Photometric measurement was performed in the absorbance/reflectance mode with CAMAG TLC scanner 3 connected to computer running CATS4 software. The absorbance/reflectance spectrum of the compound was scanned and a maxima was selected at 284 nm for quantification. The calibration curve was prepared by plotting peak area vs. respective concentration. (Figure-1)

 

Figure-1: Chromatogram showing peaks for Aceclofenac    (a) 50ng, (b) 75ng, (c) 100ng, (d) 125ng, (e) 150ng

 

Method Validation:

The method was validated as per ICH guidelines in terms of linearity, interday  and intraday precision, repeatability of measurement of peak area and peak height, repeatability of sample application, specificity, limit of detection and limit of quantification for aceclofenac.

 

The linearity range was determine by applying standard solution of aceclofenac in calibration range (50ng to 150ng) on TLC plate, developed and analyzed as described (n=5). Repeatability of measurement of peak area and peak height determined (n=7) by spotting 25µl (125ng/spot) of standard solution of aceclofenac on TLC plate and developed and analyzed. The area and height of the spot was measured without changing plate position and the %CV of the data obtained was calculated. Repeatability of sample application (n=7) was determined by spotting 25μl (125ng/spot) of standard solution of aceclofenac on TLC plate and analyzed. The area and height of the seven spots were measured and the %CV of obtained data was computed. The intraday (n=3) precision (% CV) was determined for standard solution of aceclofenac (50-150 ng/spot). The inter day (n=5) precision (% CV) was determined for standard solution of aceclofenac (50-150 ng/spot) for five consecutive days.

Limit of detection was determined by spotting 5, 10, 15, 20, 25 and 30µl of a solution of aceclofenac (1µg/ml) on TLC plate, developed and analyzed. The peak purity of the proposed method was checked by evaluating correlation between spectra of aceclofenac scanned at peak start, peak apex and peak end position.

Photodegradation kinetics of Aceclofenac in methanol:

Aceclofenac (10mg) was accurately weighed and transferred into 10 ml volumetric flask (previously cleaned and wrapped with aluminum foil). It was dissolved and diluted to volume with methanol. This solution (1ml) was further diluted with methanol to volume in 10 ml volumetric flask (100µg/ml). Five ml of standard stock solution was diluted further with methanol to volume in 50 ml volumetric flask (10μg/ml). The solution was irradiated in sunlight (Room temperature 38±2oC). Five ml of sample was transferred at 0, 30, 60, 90, 120, 150, 180, 210, and 240 min. interval in a series of clean dry 10ml volumetric flask and diluted to the mark with methanol and preserved in refrigerator until analyzed. At the time of analysis, samples were removed from freezer and allowed to acquire room temperature. 25μl (125ng/spot) of each of the solution along with standard aceclofenac solution was spotted on prewashed silica gel TLC plate developed and analyzed as described.

 

RESULTS AND DISCUSSION:

Aceclofenac is an anti-inflammatory drug act as preferential Cox-2 enzyme inhibitors. Various HPLC method, HPTLC method, spectrophotometric method and phototoxicity study of aceclofenac were reported in literature. HPTLC method was used successfully to estimate aceclofenac in a photodegraded sample. Aceclofenac is not soluble in an aqueous solvent and freely soluble in methanol. Therefore methanol was used as solvent. It was observed that presaturation for 45 minutes with mobile phase, toluene: ethyl acetate: glacial acetic acid:  methanol (6.00:1:00.20.00:0.15 v/v/v/v) was required to obtain reproducibility. The optimized mobile phase gives well-separated peaks of aceclofenac at Rf value 0.35±0.03.

 

Linearity range of aceclofenac was found in range of 50-150ng/spot with co-relations coefficient of 0.9987 (n=5). The linear regression equation is Y= 25.745X + 7.168 for peak area. For repeatability of measurement (n=7) of peak area and peak height the corresponding %CV values were 0.57 and 0.74, which are below than their prescribed limit (< 1). For repeatability of sample application (n=7), peak area and peak height gave %CV of 1.99 and 2.29 respectively which are also below than their prescribed limit (3%). The day to day (inter day, n=5) and intraday (n=3) %CV for aceclofenac varies from 2.0 to 4.7 and 0.95 to 2.88 % respectively. The limit of detection was 25ng / spot and the limit of quantification was 50ng/spot. Peak purity check shows correlation between spectra scanned at peak start, peak apex and peak end position (rstart.apex = 0.9998 and rapex.end = 0.9997) of aceclofenac peak which confirmed that the peak represents a pure single components that is aceclofenac (Figure-2). All method validation parameters are summarized in Table-1

 

Figure-2: Peak purity spectrum of Aceclofenac

 

Table No.1 - Summary of validation parameters

Sr. No.

Parameters

Results

1

Linearity

0.9987

2

Precision (% C.V.)

·     Repeatability of measurement

o  height

o  area

·     Repeatability of sample application

o  height

o  area

·     Interday (n=5)

·     Intraday (n=3)

 

 

0.57

0.74

 

1.99

2.99

2.0-4.7

0.95-2.88

3

Range

50-150 ng/spot

4

Limit of Detection

15 ng/spot

5

Limit of Quantification

50 ng /spot

6

Specificity

Specific

 

The photodegradation of aceclofenac was carried out in methanol in sunlight. Appropriate amount of aceclofenac was degraded on exposure to sunlight indicated the finite rate of degradation reaction. Aceclofenac remaining after sunlight exposure was determined at various intervals by HPTLC (Table-2). The data obtained at various time intervals fit into the zero order rate kinetics. The rate constant observed for three times (n=3) measurement for photodegradation of aceclofenac were almost same, indicating the rate of degradation follows zero order kinetics. Similarly when the data of aceclofenac retained Vs irradiation time was plotted gave straight line (Figure-3). Results clearly indicate that photodegradation of aceclofenac follows zero order kinetics. The rate constant (K) observes is 0.4856 ng μl-1 min-1. T1/2 and T90% is found to be 116.78 min-1 and 23.35 min-1 respectively. The peak purity of aceclofenac left after photodegradation was determined by comparing spectrum at three different levels i.e. peak start peak apex and peak end. A good correlation 0.9933 (Figure-4) was found between pure aceclofenac and aceclofenac steadily after Photodegradation.

 

Figure-3: Kinetics of Aceclofenac photodegradation

 

Figure-4: Peak purity spectrum of aceclofenac after photodegradation

 

Table No. - 2: Determination of Rate order and Rate constant

Time (min)

 

Area

 

Concentration (ng)

 

K

(ng μl-1min-1)

0

2855

113.4031775

---

30

2614

104.1545782

0.308180

60

2275

91.14513777

0.370914

90

1744

70.76751861

0.473694

120

1318

54.41937217

0.491505

150

943

40.02839819

0.489144

180

603

26.98058178

0.480107

 

 

 

Average=0.485591

 

REFERENCES:

1.       Rang HP, Dale MM and Ritter JM. Anti-inflammatory and immunosuppressant drugs. In Rang and Dale’s. Pharmacology, Edited by Churchill Livingstone, Elsevier, New York. 2003; 5th ed: pp. 217.

2.       British Pharmacopoeia. Medicine commission. U.K. 2002; 1: 5-7.

3.       European Pharmacopoeia 5.0. Council of Europe. Strasbourg. 2005; 909-912.

4.       Jin Y, Chen H and Zeng F. Determination of Aceclofenac in human plasma by reversed-phase high performance liquid chromatography. J. Se. Pu. 2004; 22: 252-254.

5.       Hinz B, Auge D, Rau T and Rietbrock S. Simultaneous determination of Aceclofenac and three of its metabolite in human plasma by high performance liquid chromatography. Biomed. Chromatogr. 2003; 17: 268-275.

6.       Lee HS , Jeong CK, Choi SJ and Kim SB. Simultaneous determination of Aceclofenac and Diclofenac in human plasma by Narrowbore HPLC using column-switching. J. Pharm. Biomed. Anal. 2000; 23: 775-783.

7.       Momin, MY, Yeole  PG, Puranik  MP and Wadher, SJ. Reverse phase HPLC method for determination of aceclofenac and paracetamol in tablet dosage form. Ind. Jour. Pharm. Sci. 2006; 68(3): 387-389.

8.       Harikrishnan N, Gunasekaran V, Sathishbabu A, Srinivasarao G and Roosewelt C. Validated high performance liquid chromatography method for simultaneous estimation of paracetamol and aceclofenac in tablet dosage forms.  Asian J. Chem. 2007; 19(7): 5596-5600.

9.       Shaikh KA and Devkhile AB. Department of Chemistry, Yeshwant Mahavidyalaya, Swami Ramanad. Simultaneous Determination of Aceclofenac, Paracetamol, and Chlorzoxazone by RP-HPLC in Pharmaceutical Dosage Form. J. Chromatograp. Sci. 2008; 46(7):  649-652.

10.     Shaikh  KA and Devkhile AB. A simple and sensitive stability-indicating RP-HPLC assay method for the determination of aceclofenac. J. Chromatograp. Sci. 2008; 46(5):  440-444.

11.     Saharty E, Refaat M and Khateeb E. Stability-indicating spectrophotometric and Densitometric Methods for Determination Aceclofenac. Drug Develop. Ind. Pharm. 2002; 28: 118-122.

12.     Harikrishnan  N, Gunasekaran V, Sathishbabu A and Rao  G. Simultaneous estimation of aceclofenac and paracetamol by HPTLC in pure and pharmaceutical dosage form. Asian J. Chem. 2007; 19(7): 5596-5600.

13.     Abdul AM, El-Kousy E and El-Moghazy A. Determination of Aceclofenac in bulk and pharmaceutical formulation. J. Pharm. Biomed. Anal. 2002; 27: 243-251.

14.     El-Kousy NM. Spectrophotometric and spectrofluorimetric determination of etodolac and Aceclofenac. J. Pham.  Biomed. Anal. 1999; 20: 185-188.

15.     Hasan NY, Abdel-Elkawy M, Elzeany BE and Wagieh NE. Stability indicating methods for the determination of Aceclofenac. Farmaco. 2003; 58: 91-94.

16.     Zinellu A, Carru C, Sotagia S, Porqueddu E and Enrico P. Separation of aceclofenac and diclofenac in human plasma by free zone capillary electrophoresis using N-methyl-d-glucamine as an effective electrolyte additive. Eur. J. Pharm. Sci. 2005; 24: 375-377.

17.     Goyal A and Singhvi I. Visible spectrophotometric determination of aceclofenac in tablet formulation.  Asian J. Chem. 2006; 18(4): 3157-3159.

18.     Saravanan VS, Ware, Agasti L and Gopal N. UV-spectrophotometric determination of aceclofenac in tablets.  Asian J. Chem. 2006; 18(4): 3251-3252.

19.     Sankar D, Gowri P, Joy B and Anil L. Spectrophotometric determination of Aceclofenac and Famciclovir. Int. J. Chem. Sci. 2006; 4(3): 725-728.

20.     Mishra Pradeep and Garg Gopal. Simultaneous estimation of aceclofenac and paracetamol in tablets. J. Ind. Chem. Soc. 2006; 83(3): 288-290.

21.     Mishra Pradeep and Garg Gopal. Spectrophotometric estimation of aceclofenac in tablets. J. Ind. Chem. Soc. 2006; 83(1): 103-104.

22.     Nikam AD, Pawar SS and Gandhi SV. Simultaneous spectrophotometric estimation of aceclofenac and paracetamol. Asian J. Chem. 2007; 19(7): 5075-5080.

23.     Wadher SJ, Momin MY, Puranik MP and Yeole PG. Simultaneous estimation of aceclofenac and paracetamol in combined dosage form by two wavelength spectrophotometry. Pharma Review. 2007; 5(30): 164-166.

24.     Wadher SJ, Momin MY, Puranik MP and Yeole PG. Spectrophotometric estimation of aceclofenac and paracetamol in combined dosage form. Ind. Pharmacist. 2007; 6(62): 89-91.

25.     Harikrishnan N, Kalaivani K, Meher V, Gunasekaran V and Roosewelt C. Simultaneous estimation of paracetamol, aceclofenac and chlorzoxazone in oral dosage form using spectrophotometric method. Anal. Chem. 2007; 5(1-6): 46-50.

26.     Jain Anurekha, Jain Avijeet, Vyas Vivek, Subedar Niharika and Gupta Arun. Simultaneous estimation of aceclofenac and paracetamol in tablet dosage form by UV spectroscopy.  Asian J. Chem. 2007; 19(6): 4920-4922.

27.     Patro SS, Santra S, Kumar BVV, Ravi, Rao MEB and Panda TK. Spectrophotometric method for the determination of aceclofenac in bulk and pharmaceutical dosage forms.  Acta Ciencia Indica Chem. 2007; 33(3): 317-318.

28.     Dashora K, Garg G and Saraf S. Spectrophotometric determination of aceclofenac and tizanidine hydrochloride.  Asian J. Chem. 2007; 19(4): 3289-3291.

29.     Acuna JA, Vazquez MD and Tascon ML. Polarographic behavior of Aceclofenac, Tenoxicam and Droxicam. J. Pharm. Biomed. Anal. 2004; 36: 157-158

30.     Posac JR, Vazquez MD and Tascon ML. Determination of Aceclofenac using adsorptive stripping Voltametric techniques on conventional and surfactant chemically modified carbon paste electrodes. Talanta. 1995; 42: 200-206

31.     Patel NK. Estimation and photodegradation study of aceclofenac by HPTLC. M.Pharm thesis. Gujarat University, September 2005; 51-56

32.     Chen Li-sheng, Yang Jing-hua and Zhou Zu-kun. Determination of residual organic solvents in aceclofenac by gas chromatography. Zhongguo Xinyao Zazhi 2006; 15(14): 1193-1194.

33.     Kang Wonku and Kim Eun-Young. Simultaneous determination of aceclofenac and its three metabolites in plasma using liquid chromatography-tandem mass spectrometry. J. Pharm. Biomed. Ana. 2008; 46(3):  587-591.

34.     Vargas F, Rivas C, Zoltan T, Fuentes A and Padron L. Photodegradation and in vitro phototoxicity of aceclofenac. Die Pharmazie. 2007; 62(5): 337-341.

 


 

 

Received on 21.11.2009        Modified on 29.12.2009

Accepted on 30.01.2010        © AJRC All right reserved